2-13
2.6 ZEROING PROCEDURES - Continued
g. Fire a 3-round shot group and note the center of the
shot group relative to the designated strike point.
Retighten the integral rail grabber bracket.
h. Rotate the Boresight Adjusters to move the center of
the shot group to the designated strike point.
i. Fire another 3-round shot group and again observe
the center of the new shot group relative to the
designated strike point.
j. For all weapons except the M249, when 5 out of 6
consecutive rounds are in the designated strike
zone, the MIPIM / weapon combination is zeroed.
For the M249, the MIPIM / weapon combination is
zeroed when 5 out of 12 non-consecutive rounds are
within a 6cm square.